{"_buckets": {"deposit": "f7d8daa9-3ea1-4d8c-bf66-feb3cca64003"}, "_deposit": {"created_by": 1, "id": "31567", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "31567"}, "status": "published"}, "_oai": {"id": "oai:jaxa.repo.nii.ac.jp:00031567", "sets": ["1890", "1910"]}, "author_link": ["404962", "404960", "404964", "404963", "404961", "404958", "404957", "404959", "404956", "404955"], "item_9_alternative_title_2": {"attribute_name": "その他のタイトル(英)", "attribute_value_mlt": [{"subitem_alternative_title": "Some devices serving the data acquisition of rapid processes"}]}, "item_9_biblio_info_10": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1975-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3_A", "bibliographicPageEnd": "557", "bibliographicPageStart": "545", "bibliographicVolumeNumber": "11", "bibliographic_titles": [{"bibliographic_title": "東京大学宇宙航空研究所報告"}]}]}, "item_9_description_16": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "衝撃波管法をはじめとする高速反応の研究に用いるエレクトロニクスについて報告する.入射衝撃波の速度測定を目的とする多点間の時間間隔を継続して測定できるカウンタと,それを使った測定例を示した高速反応のデータ収録系としてオフラインでミニコンピュータに結合する汎用高速ディジタルレコーダを製作した.これは繰返しトリガによる断続的なデータの多数回収録も可能である.", "subitem_description_type": "Abstract"}]}, "item_9_description_17": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "An electronic counter which can indicate the time intervals between successive pulses is applied to the measurement of the speed of incident shock wave by platinum film gauges, piezoelectric gauges and schlieren methods. A universal digital recorder is also assembled to compile such rapid transient phenomena as the pressure charge in a shock tube and the variation of infrared spectra obtained by rapid scanning. That, is, the intensities of the selected spectral region are digitalized at a definite interval and stored in predetermined number of addresses by a trigger which indicates the start of each scan. The cycle of this operation is repeated by the multiple trigger singnals until all memories are filled with the spectral intensities. The universal digital recorder is also available to count and record the change in the number of discrete pulses produced by an ion detector during the scanning of a Q- pole mass filter.", "subitem_description_type": "Other"}]}, "item_9_description_32": {"attribute_name": "資料番号", "attribute_value_mlt": [{"subitem_description": "資料番号: SA0124505000", "subitem_description_type": "Other"}]}, "item_9_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "東京大学宇宙航空研究所"}]}, "item_9_source_id_21": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0563-8100", "subitem_source_identifier_type": "ISSN"}]}, "item_9_source_id_24": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00161914", "subitem_source_identifier_type": "NCID"}]}, "item_9_text_34": {"attribute_name": "メタデータ提供者", "attribute_value_mlt": [{"subitem_text_value": "メタデータ提供者: ISASNII"}]}, "item_9_text_35": {"attribute_name": "JAXAカテゴリ", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ: 宇宙科学研究所"}]}, "item_9_text_43": {"attribute_name": "DSpaceコレクション番号", "attribute_value_mlt": [{"subitem_text_value": "DSpaceコレクション番号: 6"}]}, "item_9_text_6": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "東京大学宇宙航空研究所"}, {"subitem_text_value": "東京大学宇宙航空研究所"}, {"subitem_text_value": "東京大学宇宙航空研究所"}, {"subitem_text_value": "東京大学宇宙航空研究所"}, {"subitem_text_value": "東京大学宇宙航空研究所"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "山下, 雅道"}], "nameIdentifiers": [{"nameIdentifier": "404955", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐野, 芳徳"}], "nameIdentifiers": [{"nameIdentifier": "404956", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田中, 通"}], "nameIdentifiers": [{"nameIdentifier": "404957", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小倉, 啓男"}], "nameIdentifiers": [{"nameIdentifier": "404958", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "倉谷, 健治"}], "nameIdentifiers": [{"nameIdentifier": "404959", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "YAMASHITA, Masamichi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "404960", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SANO, Yoshinori", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "404961", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TANAKA, Toru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "404962", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OGURA, Hiroo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "404963", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KURATANI, Kenji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "404964", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-01-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "SA0124505.pdf", "filesize": [{"value": "803.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 803000.0, "url": {"label": "SA0124505.pdf", "url": "https://jaxa.repo.nii.ac.jp/record/31567/files/SA0124505.pdf"}, "version_id": "275c6bde-a38e-46ca-a146-82ef70dddd71"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "衝撃波速度の測定と高速データ収録系の製作", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "衝撃波速度の測定と高速データ収録系の製作"}]}, "item_type_id": "9", "owner": "1", "path": ["1890", "1910"], "permalink_uri": "https://jaxa.repo.nii.ac.jp/records/31567", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-26"}, "publish_date": "2015-03-26", "publish_status": "0", "recid": "31567", "relation": {}, "relation_version_is_last": true, "title": ["衝撃波速度の測定と高速データ収録系の製作"], "weko_shared_id": -1}
衝撃波速度の測定と高速データ収録系の製作
https://jaxa.repo.nii.ac.jp/records/31567
https://jaxa.repo.nii.ac.jp/records/31567c1d0fde4-5cb8-4a32-a4e2-e5e1ad9b889e
名前 / ファイル | ライセンス | アクション |
---|---|---|
SA0124505.pdf (803.0 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-26 | |||||
タイトル | ||||||
タイトル | 衝撃波速度の測定と高速データ収録系の製作 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
その他のタイトル(英) | ||||||
その他のタイトル | Some devices serving the data acquisition of rapid processes | |||||
著者 |
山下, 雅道
× 山下, 雅道× 佐野, 芳徳× 田中, 通× 小倉, 啓男× 倉谷, 健治× YAMASHITA, Masamichi× SANO, Yoshinori× TANAKA, Toru× OGURA, Hiroo× KURATANI, Kenji |
|||||
著者所属 | ||||||
東京大学宇宙航空研究所 | ||||||
著者所属 | ||||||
東京大学宇宙航空研究所 | ||||||
著者所属 | ||||||
東京大学宇宙航空研究所 | ||||||
著者所属 | ||||||
東京大学宇宙航空研究所 | ||||||
著者所属 | ||||||
東京大学宇宙航空研究所 | ||||||
出版者 | ||||||
出版者 | 東京大学宇宙航空研究所 | |||||
書誌情報 |
東京大学宇宙航空研究所報告 巻 11, 号 3_A, p. 545-557, 発行日 1975-08 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 衝撃波管法をはじめとする高速反応の研究に用いるエレクトロニクスについて報告する.入射衝撃波の速度測定を目的とする多点間の時間間隔を継続して測定できるカウンタと,それを使った測定例を示した高速反応のデータ収録系としてオフラインでミニコンピュータに結合する汎用高速ディジタルレコーダを製作した.これは繰返しトリガによる断続的なデータの多数回収録も可能である. | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | An electronic counter which can indicate the time intervals between successive pulses is applied to the measurement of the speed of incident shock wave by platinum film gauges, piezoelectric gauges and schlieren methods. A universal digital recorder is also assembled to compile such rapid transient phenomena as the pressure charge in a shock tube and the variation of infrared spectra obtained by rapid scanning. That, is, the intensities of the selected spectral region are digitalized at a definite interval and stored in predetermined number of addresses by a trigger which indicates the start of each scan. The cycle of this operation is repeated by the multiple trigger singnals until all memories are filled with the spectral intensities. The universal digital recorder is also available to count and record the change in the number of discrete pulses produced by an ion detector during the scanning of a Q- pole mass filter. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0563-8100 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00161914 | |||||
資料番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 資料番号: SA0124505000 |