JAXA Repository / AIREX 未来へ続く、宙(そら)への英知
48133007.pdf1.64 MB
title南極周回気球(PPB)に搭載した磁力計システムによる磁場観測実験
Other TitleMeasurement of geomagnetic field by fluxgate magnetometer system onboard Polar Patrol Balloons (PPB)
Author(jpn)西尾 泰穂; 遠山 文雄; 山岸 久雄; 門倉 昭; 佐藤 夏雄; 山上 隆正; 斎藤 芳隆; 並木 道義; 松坂 幸彦
Author(eng)Nishio, Yasuho; Toyama, Fumio; Yamagishi, Hisao; Kadokura, Akira; Sato, Natsuo; Yamagami, Takamasa; Saito, Yoshitaka; Namiki, Michiyoshi; Matsuzaka, Yukihiko
Author Affiliation(jpn)東海大学 工学部; 東海大学 工学部; 国立極地研究所; 国立極地研究所; 国立極地研究所; 宇宙航空研究開発機構 宇宙科学研究本部; 宇宙航空研究開発機構 宇宙科学研究本部; 宇宙航空研究開発機構 宇宙科学研究本部; 宇宙航空研究開発機構 宇宙科学研究本部
Author Affiliation(eng)Tokai University School of Engineering; Tokai University School of Engineering; National Institute of Polar Research; National Institute of Polar Research; National Institute of Polar Research; Japan Aerospace Exploration Agency Institute of Space and Astronautical Science; Japan Aerospace Exploration Agency Institute of Space and Astronautical Science; Japan Aerospace Exploration Agency Institute of Space and Astronautical Science; Japan Aerospace Exploration Agency Institute of Space and Astronautical Science
Issue Date2005-02-28
PublisherJapan Aerospace Exploration Agency (JAXA)
宇宙航空研究開発機構
Publication title大気球研究報告
Research Reports on High Altitude Balloons
Start page89
End page98
Publication date2005-02-28
Languagejpn
AbstractThe Polar Patrol Balloon (PPB: Polar Patrol Balloon) Project that was planned for the polar geophysical observations was carried out by the 44-th Japanese Antarctic Research Expedition at Syowa Base, Antarctica in January 2003. Fluxgate magnetometer system was loaded on 3 balloons and the geomagnetic field was measured. It is very difficult to detect vector perturbations of the geomagnetic field by balloon because the motion of the sensors during the flight is irregular and complex. A high resolution fluxgate magnetometer system has been developed that is composed with 8-directional sun pulse sensor, 2-axial clinometer and a pulse clock counter. Two PPBs were launched on 13th January 2003. Their flights were apart 150 km from each other and at an altitude of 31.5 km. It was possible to get 2 magnetometers data for 11 days and 25 days respectively. As a result, the attitude change of the gondola were detected but small perturbation of magnetic field vector was undetected because of balloons were not rotated due to spin motor trouble. Here described are the new magnetometer system and results of magnetometer data analysis.
2003年1月に第44次南極観測隊によって、3機の南極周回気球(PPB: Polar Patrol Balloon)が昭和基地から打ち上げられ、地球物理観測を行った。気球には地磁気観測の目的でフラックスゲート磁力計システムが搭載された。気球による地磁気の精密な成分測定は、飛翔中のセンサの運動が不規則かつ複雑なことから非常に困難である。8方位太陽センサと2軸傾斜計とパルスクロックカウンターから成る高精度フラックスゲート磁力計システムを開発した。2機の気球は2003年1月13日に打ち上げられ、150km離れて高度31.5kmで飛行した。2機に搭載した磁力計からはそれぞれ11日間と25日間の磁場データが得られた。その結果、ゴンドラの姿勢変化は検出されたが、気球のスピンモーターの異常でゴンドラが回転せず、地磁気ベクトルの微小変動は検出できなかった。ここでは、新たな磁場計測システムと得られた結果について報告する。
DescriptionJAXA Research and Development Report
宇宙航空研究開発機構研究開発報告
Keywordsmagnetometer; geomagnetic field; Polar Patrol Balloon; JARE44; Syowa Station; sun pulse sensor; high resolution; observation; 磁力計; 地磁気; 南極周回気球; JARE44; 昭和基地; 太陽パルスセンサ; 高分解能; 観測
Document TypeTechnical Report
JAXA Category研究開発報告
ISSN1349-1113
SHI-NOAA0048133007
Report NoJAXA-RR-04-015
URIhttps://repository.exst.jaxa.jp/dspace/handle/a-is/29520


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.