| タイトル | Dosimetric results on EURECA |
| 本文(外部サイト) | http://hdl.handle.net/2060/19950017380 |
| 著者(英) | Reitz, G. |
| 著者所属(英) | Deutsche Forschungsanstalt fuer Luft- und Raumfahrt |
| 発行日 | 1995-02-01 |
| 言語 | eng |
| 内容記述 | Detector packages were exposed on the European Retrievable Carrier (EURECA) as part of the Biostack experiment inside the Exobiology and Radiation Assembly (ERA) and at several locations around EURECA. The packages consist of different plastic nuclear track detectors, nuclear emulsions and thermoluminescence dosimeters (TLD's). Evaluation of these detectors yields data on absorbed dose and particle and LET spectra. Preliminary results of absorbed dose measurements in the EURECA dosimeter packages are reported and compared to results of the LDEF experiments. The highest dose rate measured on EURECA is 63.3 plus or minus 0.4 mGy d(exp -1) behind a shielding thickness of 0.09 g cm(exp -2) in front of the detector package. |
| NASA分類 | SPACE RADIATION |
| レポートNO | 95N23800 |
| 権利 | No Copyright |
| URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/107923 |