タイトル | Milestone 5 test report. Task 5, subtask 5.2: Tile to foam strength tests |
本文(外部サイト) | http://hdl.handle.net/2060/19950009498 |
著者(英) | Greenberg, H. S. |
著者所属(英) | Hercules, Inc.; Rockwell International Corp. |
発行日 | 1994-12-02 |
言語 | eng |
内容記述 | This report summarizes work that has been performed to date on the strength of a cryotank insulation system using Rohacell foam and TUFI-coated AETB-12 ceramic tiles directly bonded to a simulated graphite-epoxy tank wall. Testing utilized a custom specimen design which consists of a long tensile specimen with eccentric loading to induce curvature similar to the curvature expected due to 'pillowing' of the tank when pressurized. A finite element model was constructed to predict the specific element strains in the test article, and to assist with design of the test specimen to meet the specific goals of curvature and laminate strain. The results indicate that the heat treated 3.25-pcf density Rohacell foam does not provide sufficient strength for the induced stresses due to curvature and stress concentration at the RTV bondline to the TUFI tile. The test was repeated using higher density non-heat treated Rohacell foam (6.9 pcf) without foam failure. The finite element model was shown to predict specimen behavior, and validation of the model was successful. It is pertinent to mention that the analyses described herein accurately predicted the failure of the heat treated foams and based on this analysis method it is expected that the untreated 3.25 pcf Rohacell foam will be successful. |
NASA分類 | STRUCTURAL MECHANICS |
レポートNO | 95N15913 NASA-CR-197241 NAS 1.26:197241 SSD94D0298 |
権利 | No Copyright |
|