タイトル | Pointing/roll mechanism for the ultraviolet coronagraph spectrometer |
本文(外部サイト) | http://hdl.handle.net/2060/19910015296 |
著者(英) | Guy, Larry J.; Ostaszewski, Miroslaw A. |
著者所属(英) | Ball Corp. |
発行日 | 1991-05-01 |
言語 | eng |
内容記述 | A pointing/roll mechanism for the Ultraviolet Coronagraph Spectrometer (UVCS) is presented along with a description of the mechanism control algorithm. The mechanism, operating in space, will position the 2.1 meter long, 0.7 meter diameter UVCS instrument in pitch and yaw, within a 54 arc-minute half angle cone, and will also allow it to rotate + or - 179.75 deg. After considerable design effort, an optimum mechanical solution was achieved, which meets all scientific requirements as well as weight, volume, and power budgets. Evolution of the mechanism is presented along with the design status. |
NASA分類 | SPACECRAFT INSTRUMENTATION |
レポートNO | 91N24610 |
権利 | No Copyright |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/132260 |
|