| タイトル | Environmental monitoring for Space Station WP01 |
| 本文(外部サイト) | http://hdl.handle.net/2060/19890006421 |
| 著者(英) | Zwiener, J. M. |
| 著者所属(英) | NASA Marshall Space Flight Center |
| 発行日 | 1988-11-01 |
| 言語 | eng |
| 内容記述 | External contamination monitoring instrumentation for the Space Station work package one (WP01) elements, were imposed on the contractor as deliverable hardware. The monitoring instrumentation proposed by the WP01 contractor in response to the contract requirement includes both real time measurements and passive samples. Real time measurement instrumentation consists of quartz crystal microbalances for molecular deposition, ion gaseous species identification. Internal environmental contamination monitoring for particulates is included in both Lab and HAB modules. Passive samples consists of four sample mounting plates mounted external to the Space Station modules, two on the U.S. LAB, and two on the HAB module. |
| NASA分類 | SPACECRAFT DESIGN, TESTING AND PERFORMANCE |
| レポートNO | 89N15792 |
| 権利 | No Copyright |
| URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/143773 |