タイトル | Cryogenic cooling study for the advanced limb scanner |
本文(外部サイト) | http://hdl.handle.net/2060/19800015130 |
著者(英) | Russo, S. C. |
著者所属(英) | Hughes Aircraft Co. |
発行日 | 1980-05-01 |
言語 | eng |
内容記述 | The cryogenic operating requirements for a VM refrigerator to be used for detector cooling of the advanced limb scanner (ALS) instrument are defined. Determination of these requirements include consideration of mission and environmental constraints. Based on the operating requirements a detailed refrigerator design and performance analysis is conducted resulting in an optimized VM refrigerator conceptual design. The cooler-instrument-spacecraft interfaces are evaluated resulting in recommendations as to the best approach and most effective concepts resulting in simple and satisfactory interfaces. A preliminary implementation plan and schedule describing the general tasks required to develop, design, manufacture, test, and deliver three VM coolers and required support equipment to support an ALS flight experiment are presented. The result of this effort shows that existing VM cooler technology is sufficient to satisfy ALS mission requirements and schedules. |
NASA分類 | INSTRUMENTATION AND PHOTOGRAPHY |
レポートNO | 80N23621 NASA-CR-159250 |
権利 | No Copyright |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/172594 |
|