タイトル | Acoustic tests of duct-burning turbofan jet noise simulation |
本文(外部サイト) | http://hdl.handle.net/2060/19780020100 |
著者(英) | Brausch, J. F.; Staid, P. S.; Latham, D.; Knott, P. R.; Stringas, E. J.; Heck, P. H. |
著者所属(英) | General Electric Co. |
発行日 | 1978-07-01 |
言語 | eng |
内容記述 | The results of a static acoustic and aerodynamic performance, model-scale test program on coannular unsuppressed and multielement fan suppressed nozzle configurations are summarized. The results of the static acoustic tests show a very beneficial interaction effect. When the measured noise levels were compared with the predicted noise levels of two independent but equivalent conical nozzle flow streams, noise reductions for the unsuppressed coannular nozzles were of the order of 10 PNdB; high levels of suppression (8 PNdB) were still maintained even when only a small amount of core stream flow was used. The multielement fan suppressed coannular nozzle tests showed 15 PNdB noise reductions and up to 18 PNdB noise reductions when a treated ejector was added. The static aerodynamic performance tests showed that the unsuppressed coannular plug nozzles obtained gross thrust coefficients of 0.972, with 1.2 to 1.7 percent lower levels for the multielement fan-suppressed coannular flow nozzles. For the first time anywhere, laser velocimeter velocity profile measurements were made on these types of nozzle configurations and with supersonic heated flow conditions. Measurements showed that a very rapid decay in the mean velocity occurs for the nozzle tested. |
NASA分類 | AERONAUTICS (GENERAL) |
レポートNO | 78N28043 NASA-CR-2966 DOC-R77AEG524 |
権利 | No Copyright |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/178314 |
|