| タイトル | Effect of anode-cathode geometry on performance of the HIP-1 hot ion plasma |
| 本文(外部サイト) | http://hdl.handle.net/2060/19780013979 |
| 著者(英) | Lauver, M. R. |
| 著者所属(英) | NASA Lewis Research Center |
| 発行日 | 1978-04-01 |
| 言語 | eng |
| 内容記述 | Hot-ion hydrogen plasma experiments were conducted in the NASA Lewis HIP-1 magnetic mirror facility to determine how the ion temperature was influenced by the axial position of the cathode tips relative to the anodes. A steady-state EXB plasma was formed by applying a strong radially inward dc electric field near the throats of the magnetic mirrors. The dc electric field was created between hollow cathode rods inside hollow anode cylinders, both concentric with the magnetic axis. The highest ion temperatures, 900 eV, were attained when the tip of each cathode was in the same plane as the end of its anode. These temperatures were reached with 22 kV applied to the electrodes in a field of 1.1 tesla. Scaling relations were empirically determined for ion temperature and the product of ion density and neutral particle density as a function of cathode voltage, discharge current, and electrode positions. Plasma discharge current vs voltage (I-V) characteristics were determined. |
| NASA分類 | PLASMA PHYSICS |
| レポートNO | 78N21922 NASA-TP-1201 E-9386 |
| 権利 | No Copyright |
| URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/179118 |