タイトル | S-193 scatterometer backscattering cross section precision/accuracy for Skylab 2 and 3 missions |
本文(外部サイト) | http://hdl.handle.net/2060/19770009164 |
著者(英) | Krishen, K.; Pounds, D. J. |
著者所属(英) | Lockheed Electronics Co. |
発行日 | 1975-06-01 |
言語 | eng |
内容記述 | Procedures for measuring the precision and accuracy with which the S-193 scatterometer measured the background cross section of ground scenes are described. Homogeneous ground sites were selected, and data from Skylab missions were analyzed. The precision was expressed as the standard deviation of the scatterometer-acquired backscattering cross section. In special cases, inference of the precision of measurement was made by considering the total range from the maximum to minimum of the backscatter measurements within a data segment, rather than the standard deviation. For Skylab 2 and 3 missions a precision better than 1.5 dB is indicated. This procedure indicates an accuracy of better than 3 dB for the Skylab 2 and 3 missions. The estimates of precision and accuracy given in this report are for backscattering cross sections from -28 to 18 dB. Outside this range the precision and accuracy decrease significantly. |
NASA分類 | SPACECRAFT INSTRUMENTATION |
レポートNO | 77N16107 NASA-CR-144551 LEC-6119 |
権利 | No Copyright |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/183413 |