タイトル | Quiet, clean short-haul experimental engine (QCSEE) test results from a 14 cm inlet for a variable pitch fan thrust reverser |
本文(外部サイト) | http://hdl.handle.net/2060/19760013054 |
著者(英) | Vier, W. F. |
著者所属(英) | General Electric Co. |
発行日 | 1975-12-01 |
言語 | eng |
内容記述 | A 1/13th scale model of the fan discharge duct was tested with a matrix of flare exlets. Exlets are flared fan nozzles configured for improved reverse flow inlet performance for reverse pitch fan applications. Results showed that a flare type exlet is an acceptable design for QCSEE, as indicated by high pressure recovery and low distortion performance. |
NASA分類 | AIRCRAFT PROPULSION AND POWER |
レポートNO | 76N20142 R75AEG387 NASA-CR-134867 |
権利 | No Copyright |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/186594 |