タイトル | ATM C and D panel/EREP cooling system contamination problem |
本文(外部サイト) | http://hdl.handle.net/2060/19740002679 |
著者(英) | Williamson, J. G. |
著者所属(英) | NASA Marshall Space Flight Center |
発行日 | 1973-10-01 |
言語 | eng |
内容記述 | This report presents the history of a preflight contamination problem that occurred in the ATM C and D panel/EREP cooling system on the Skylab, the studies that were made to determine the cause of the problem, and corrective actions that were made prior to lift-off. The results of all the observations, analyses and laboratory testing indicated that the contamination came from one or more of the EREP tape recorder coldplates and was caused by some abnormal electrolytic action, either during bench testing or in the spacecraft. Studies indicate that no such electrolytic action is likely to occur under normal operating conditions. |
NASA分類 | SPACE VEHICLES |
レポートNO | 74N10792 NASA-TM-X-64788 |
権利 | No Copyright |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/196932 |
|