JAXA Repository / AIREX 未来へ続く、宙(そら)への英知

このアイテムに関連するファイルはありません。

タイトルDesign and experimental performance of short curved wall diffusers with axial symmetry utilizing slot suction
本文(外部サイト)http://hdl.handle.net/2060/19730011578
著者(英)Yang, T.; Nelson, C. D.; Hudson, W. G.
著者所属(英)Clemson Univ.
発行日1973-03-01
言語eng
内容記述The feasibility of designing short curved wall axially symmetrical subsonic diffusers utilizing suction through slots in the diffuser walls to prevent flow separation was investigated. A potential flow analysis was made, and a digital computer program was written for determining the diffuser wall contour for prescribed boundary conditions. The flow field included branch flow so that the suction slot geometry could be a part of the diffuser design. One bell shaped diffuser and three annular diffusers with area ratios of either 2.5:1 or 3:1 were designed, fabricated, and tested. Minimum suction requirements of metastable operation ranged from 6.3 percent to 12 percent when operating with inlet air velocities in the 1000 to 250 ft/sec (30 to 76 m/sec) range. For stable operation suction rates from 10 percent to 22 percent were required. In all cases the diffuser effectiveness was above 95 percent based on the conventional definition, and from 81 percent to 94 percent when the suction loss was accounted for. The exit velocity profiles were virtually flat with no more than + or - 9% variation over 95 percent of the exit area when operated with sufficient suction to prevent flow separation.
NASA分類FLUID MECHANICS
レポートNO73N20305
NASA-CR-2209
権利No Copyright
URIhttps://repository.exst.jaxa.jp/dspace/handle/a-is/199960


このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。