タイトル | Modification of codes NUALGAM and BREMRAD, Volume 1 |
本文(外部サイト) | http://hdl.handle.net/2060/19720016639 |
著者(英) | Steyn, J. J.; Huang, R.; Firstenberg, H. |
著者所属(英) | Nuclear Utility Services, Inc. |
発行日 | 1971-05-01 |
言語 | eng |
内容記述 | The NUGAM2 code predicts forward and backward angular energy differential and integrated distributions for gamma photons and fluorescent radiation emerging from finite laminar transport media. It determines buildup and albedo data for scientific research and engineering purposes; it also predicts the emission characteristics of finite radioisotope sources. The results are shown to be in very good agreement with available published data. The code predicts data for many situations in which no published data is available in the energy range up to 5 MeV. The NUGAM3 code predicts the pulse height response of inorganic (NaI and CsI) scintillation detectors to gamma photons. Because it allows the scintillator to be clad and mounted on a photomultiplier as in the experimental or industrial application, it is a more practical and thus useful code than others previously reported. Results are in excellent agreement with published Monte Carlo and experimental data in the energy range up to 4.5 MeV. |
NASA分類 | COMPUTERS |
レポートNO | 72N24289 NASA-CR-122407 NUS-786/1-VOL-1 |
権利 | No Copyright |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/203418 |