| タイトル | Design, performance, and evaluation of a direct-current contactor for space nuclear electrical systems |
| 本文(外部サイト) | http://hdl.handle.net/2060/19720010584 |
| 著者(英) | Mueller, L. A.; Medwid, D. W.; Koutnik, E. A.; Powell, A. H. |
| 著者所属(英) | NASA Lewis Research Center |
| 発行日 | 1972-03-01 |
| 言語 | eng |
| 内容記述 | A direct-current contactor for use in large space power systems was designed, built, and tested. It was developed to be operational in an environment of 540 C and at a pressure of 0.0001 N/sq m or lower. The contactor is rated to pass 10 A continuously and to interrupt a 20-A current at 10,000 V. It was tested to determine the corona threshold level and the leakage current at different temperatures. Also, it was tested for its closing and interruption ability. |
| NASA分類 | ELECTRONICS |
| レポートNO | 72N18234 NASA-TN-D-6699 E-6627 |
| 権利 | No Copyright |
| URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/204064 |