タイトルTesting of the Geoscience Laser Altimeter System (GLAS) Prototype Loop Heat Pipe
本文(外部サイト)http://hdl.handle.net/2060/19990004126
著者(英)Ku, Jentung; Douglas, Donya; Kaya, Tarik
著者所属(英)NASA Goddard Space Flight Center
発行日1998-01-01
1998
言語eng
内容記述This paper describes the testing of the prototype loop heat pipe (LHP) for the Geoscience Laser Altimeter System (GLAS). The primary objective of the test program was to verify the loop's heat transport and temperature control capabilities under conditions pertinent to GLAS applications. Specifically, the LHP had to demonstrate a heat transport capability of 100 W, with the operating temperature maintained within +/-2K while the condenser sink was subjected to a temperature change between 273K and 283K. Test results showed that this loop heat pipe was more than capable of transporting the required heat load and that the operating temperature could be maintained within +/-2K. However, this particular integrated evaporator-compensation chamber design resulted in an exchange of energy between the two that affected the overall operation of the system. One effect was the high temperature the LHP was required to reach before nucleation would begin due to inability to control liquid distribution during ground testing. Another effect was that the loop had a low power start-up limitation of approximately 25 W. These Issues may be a concern for other applications, although it is not expected that they will cause problems for GLAS under micro-gravity conditions.
NASA分類Fluid Mechanics and Heat Transfer
レポートNOAIAA Paper 99-0473
権利No Copyright
URIhttps://repository.exst.jaxa.jp/dspace/handle/a-is/228111


このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。