タイトル | Overview of the International Space Station System Level Trace Contaminant Injection Test |
本文(外部サイト) | http://hdl.handle.net/2060/19980058812 |
著者(英) | Perry, Jay L.; Franks, Gerald D.; Tatara, James D. |
著者所属(英) | NASA Marshall Space Flight Center |
発行日 | 1997-01-01 1997 |
言語 | eng |
内容記述 | Trace contaminant control onboard the International Space Station will be accomplished not only by the Trace Contaminant Control Subassembly but also by other Environmental Control and Life Support System subassemblies. These additional removal routes include absorption by humidity condensate in the Temperature and Humidity Control Condensing Heat Exchanger and adsorption by the Carbon Dioxide Removal Assembly. The Trace Contaminant Injection Test, which was performed at NASA's Marshall Space Flight Center, investigated the system-level removal of trace contaminants by the International Space Station Atmosphere Revitalization, and Temperature/Humidity Control Subsystems, (November-December 1997). It is a follow-on to the Integrated Atmosphere Revitalization Test conducted in 1996. An estimate for the magnitude of the assisting role provided by the Carbon Dioxide Removal Assembly and the Temperature and Humidity Control unit was obtained. In addition, data on the purity of Carbon Dioxide Removal Assembly carbon dioxide product were obtained to support Environmental Control and Life Support System Air Revitalization Subsystem loop closure. |
NASA分類 | Man/System Technology and Life Support |
レポートNO | NASA/TM-1997-208137 NAS 1.15:208137 |
権利 | Copyright, Distribution as joint owner in the copyright |