タイトル | Use of ultrasound in altitude decompression modeling |
著者(英) | Pilmanis, Andrew A.; Olson, Robert M. |
著者所属(英) | Krug Life Sciences, Inc. |
発行日 | 1993-02-01 |
言語 | eng |
内容記述 | A model that predicts the probability of developing decompression sickness (DCS) with various denitrogenation schedules is being developed by the Armstrong Laboratory, using human data from previous exposures. It was noted that refinements are needed to improve the accuracy and scope of the model. A commercially developed ultrasonic echo imaging system is being used in this model development. Using this technique, bubbles images from a subject at altitude can be seen in the gall bladder, hepatic veins, vena cava, and chambers of the heart. As judged by their motion and appearance in the vena cava, venous bubbles near the heart range in size from 30 to 300 M. The larger bubbles skim along the top, whereas the smaller ones appear as faint images near the bottom of the vessel. Images from growing bubbles in a model altitude chamber indicate that they grow rapidly, going from 20 to 100 M in 3 sec near 30,000 ft altitude. Information such as this is valuable in verifying those aspects of the DCS model dealing with bubble size, their growth rate, and their site of origin. |
NASA分類 | MAN/SYSTEM TECHNOLOGY AND LIFE SUPPORT |
レポートNO | 94N11540 |
権利 | No Copyright |
|