タイトル | Detection of Bi-Directionality in Strain-Gage Balance Calibration Data |
本文(外部サイト) | http://hdl.handle.net/2060/20120012535 |
著者(英) | Ulbrich, Norbert |
著者所属(英) | Jacobs Technology, Inc. |
発行日 | 2012-06-24 |
言語 | eng |
内容記述 | An indicator variable was developed for both visualization and detection of bi-directionality in wind tunnel strain-gage balance calibration data. First, the calculation of the indicator variable is explained in detail. Then, a criterion is discussed that may be used to decide which gage outputs of a balance have bi- directional behavior. The result of this analysis could be used, for example, to justify the selection of certain absolute value or other even function terms in the regression model of gage outputs whenever the Iterative Method is chosen for the balance calibration data analysis. Calibration data of NASA s MK40 Task balance is analyzed to illustrate both the calculation of the indicator variable and the application of the proposed criterion. Finally, bi directionality characteristics of typical multi piece, hybrid, single piece, and semispan balances are determined and discussed. |
NASA分類 | Aerodynamics |
レポートNO | ARC-E-DAA-TN5249 ARC-E-DAA-TN4564 |
権利 | Copyright, Distribution under U.S. Government purpose rights |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/241801 |
|