JAXA Repository / AIREX 未来へ続く、宙(そら)への英知

このアイテムに関連するファイルはありません。

タイトルCalibration for Thrust and Airflow Measurements in the CE-22 Advanced Nozzle Test Facility
本文(外部サイト)http://hdl.handle.net/2060/20100042397
著者(英)Wolter, John D.; Werner, Roger A.
著者所属(英)NASA Glenn Research Center
発行日2010-11-01
言語eng
内容記述CE-22 facility procedures and measurements for thrust and airflow calibration obtained with choked-flow ASME nozzles are presented. Six calibration nozzles are used at an inlet total pressure from 20 to 48 psia. Throat areas are from 9.9986 to 39.986 sq. in.. Throat Reynolds number varies from 1.8 to 7.9 million. Nozzle gross thrust coefficient (CFG) uncertainty is 0.25 to 0.75 percent, with smaller uncertainly generally for larger nozzles and higher inlet total pressure. Nozzle discharge coefficient (CDN) uncertainty is 0.15 percent or less for all the data. ASME nozzle calibrations need to be done before and after research model testing to achieve these uncertainties. In addition, facility capability in terms of nozzle pressure ratio (NPR) and nozzle airflow are determined. Nozzle pressure ratio of 50 or more is obtainable at 40 psia for throat areas between 20 and 30 sq. in.. Also presented are results for two of the ASME nozzles vectored at 10deg, a dead-weight check of the vertical (perpendicular to the jet axis) force measurement, a calibration of load cell forces for the effects of facility tank deflection with tank pressure, and the calibration of the metric-break labyrinth seal.
NASA分類Aircraft Propulsion and Power
レポートNOE-17398
NASA/TM-2010-216771
権利No Copyright
URIhttps://repository.exst.jaxa.jp/dspace/handle/a-is/249390


このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。