| タイトル | Mach-Number Measurement with Laser and Pressure Probes in Humid Supersonic Flow |
| 本文(外部サイト) | http://hdl.handle.net/2060/20080037568 |
| 著者(英) | Herring, G. C. |
| 著者所属(英) | NASA Langley Research Center |
| 発行日 | 2008-01-01 |
| 言語 | eng |
| 内容記述 | Mach-number measurements using a nonintrusive optical technique, laser-induced thermal acoustics (LITA), are compared to pressure probes in humid supersonic airflow. The two techniques agree well in dry flow (-35 C dew point), but LITA measurements show about five times larger fractional change in Mach number than that of the pressure-probe when water is purposefully introduced into the flow. Possible reasons for this discrepancy are discussed. |
| NASA分類 | Optics |
| 権利 | No Copyright |