JAXA Repository / AIREX 未来へ続く、宙(そら)への英知

このアイテムに関連するファイルはありません。

タイトルMyotonometry as a Surrogate Measure of Muscle Strength
著者(英)Clarke, M. S. F.; Leonard, C. T.; Sykes, J.; Kruger, E.; Feeback, D. L.; Ang, B. S.
著者所属(英)NASA Johnson Space Center
発行日2007-01-01
言語eng
内容記述Space flight-induced muscle atrophy/neuromuscular degradation and the consequent decrements in crew-member performance are of increasing concern as mission duration lengthens, and planetary exploration after extended space flight is planned. Pre- to post-flight strength measures have demonstrated that specific countermeasures, such as resistive exercise, are effective at countering microgravity-induced muscle atrophy and preventing decrements in muscle strength. However, in-flight assessment/monitoring of exercise countermeasure effectiveness will be essential during exploration class missions due to their duration. The ability to modify an exercise countermeasure prescription based on such real-time information will allow each individual crew member to perform the optimal amount and type of exercise countermeasure to maintain performance. In addition, such measures can be used to determine if a crew member is physically capable of performing a particular mission-related task during exploration class missions. The challenges faced in acquiring such data are those common to all space operations, namely the requirement for light-weight, low power, mechanically reliable technologies that make valid measurements in microgravity, in this case of muscle strength/neuromuscular function. Here we describe a simple, light-weight, low power, non-invasive device, known as the Myotonometer, that measures tissue stiffness as an indirect measure of muscle contractile state and muscle force production. Repeat myotonometer measurements made at the same location on the surface of the rectis femoris muscle (as determined using a 3D locator device, SEM plus or minus 0.34 mm) were shown to be reproducible over time at both maximal voluntary contraction (MVC) and at rest in a total of 17 sedentary subjects assessed three times over a period of seven days. In addition, graded voluntary isometric force production (i.e. 20%, 40%, 60%, 80% & 100% of MVC) during knee extension was shown to be significantly (p less than 0.01) correlated with contemporaneous myotonometer measurements made on the rectis femoris muscle in a total of 16 healthy subjects (8 males, 8 females). Further-more, this device has been operationally tested during parabolic flight demonstrating its suitability for use in a microgravity environment. Our data indicates that the Myotonometer is a viable surrogate measure of muscle contractile state/tone and of muscle strength/force production. Additional studies are required to assess the suitability of this technique for assessing these measures in de-conditioned subjects such as crew-members.
NASA分類Aerospace Medicine
権利Copyright


このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。