タイトル | Cryogenic installation status of the CRYHOLAB Test Facility |
その他のタイトル | CRYHOLABテスト施設の極低温機器取り付け現状 |
著者(日) | Saugnac, Herve; Bousson, Sebastien; Blache, P.; Commeaux, C.; Hammoudi, N.; Junquera, T.; Braud, D.; Safa, Henri; Sahuquet, P.; Loiseau, D. |
著者(英) | Saugnac, Herve; Bousson, Sebastien; Blache, P.; Commeaux, C.; Hammoudi, N.; Junquera, T.; Braud, D.; Safa, Henri; Sahuquet, P.; Loiseau, D. |
著者所属(日) | Institut de Physique Nucleaire; Institut de Physique Nucleaire; Institut de Physique Nucleaire; Institut de Physique Nucleaire; Institut de Physique Nucleaire; Institut de Physique Nucleaire; Commissariat a l'Energie Atomique; Commissariat a l'Energie Atomique; Commissariat a l'Energie Atomique; Commissariat a l'Energie Atomique |
著者所属(英) | Institut de Physique Nucleaire; Institut de Physique Nucleaire; Institut de Physique Nucleaire; Institut de Physique Nucleaire; Institut de Physique Nucleaire; Institut de Physique Nucleaire; Commissariat a l'Energie Atomique; Commissariat a l'Energie Atomique; Commissariat a l'Energie Atomique; Commissariat a l'Energie Atomique |
発行日 | 2003-06 |
刊行物名 | Proceedings of the 10th Workshop on RF Superconductivity, SRF2001 Proceedings of the 10th Workshop on RF Superconductivity, SRF2001 |
開始ページ | 632 |
終了ページ | 634 |
刊行年月日 | 2003-06 |
言語 | eng |
抄録 | In the field of SCRF activities the IPN cryogenic group, associated with the SEA and the SIG group of CEA Saclay has designed and built CRYHOLAB, a facility dedicated to the test at full power of SCRF cavities and associated components. The cryostat, 2.5 m long and 1 m diameter, is able to cool 5 cells 700 MHz cavities equipped with their helium tank and cold tuning system. Two lateral 500 mm ports allow the insertion of power couplers of various design. The cold feed box, placed onto the cryostat, and the associated cryogenic utilities (liquefier, cryogenic pipes and the 2 K bath pumping system) are designed to evacuate about 70 W dissipated on the cavity walls at 2 K. The installation of this facility is achieved and the first cryogenic tests are currently performed. CRYHOLAB is scheduled to be operational for a first cavity test in October 2001. |
キーワード | CRYHOLAB Test Facility; power coupler; superconducting cavity resonator; cold tuning system; 2 K bath pumping system; installation; heat shielding; report; thermosiphon; heat exchanger; prototype; cryostat; CRYHOLABテスト施設; パワーカプラー; 超伝導空洞共振器; 低温チューニング・システム; 2度Kバス・ポンプ・システム; 設置; 熱遮蔽; 報告; 熱サイホン; 熱交換機; プロトタイプ; クライオスタット |
資料種別 | Conference Paper |
SHI-NO | AA0046174126 |
レポートNO | KEK-Proceedings-2003-2 |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/30136 |
|