タイトルEfficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation
著者(英)Fujitaka, K.; Badhwar, G. D.; Yasuda, H.
発行日2002-01-01
2002
言語eng
内容記述Chips of a radiophotoluminescence glass dosemeter (RPLG) were used for measurements of space radiation during a 9.8 d Shuttle-Mir mission (STS-91) at an altitude of 400 km and an inclination of 51.65 degrees. Two of RPLG chips were put into each of 59 positions in or on a life-size human phantom. The RPLG values equivalent to 137Cs gamma ray absorbed doses were found to be systematically lower than those of a Mg2SiO4:Tb thermoluminescence dosemeter (TDMS). In comparison with the organ or tissue absorbed dose and dose equivalent values that were estimated using a combination of TDMS and plastic nuclear track detectors, the efficiencies of the RPLG chips were about 80% for the water absorbed dose and about 40% for the dose equivalent. Whereas the percentage values will change during different missions, such additional information obtained from small RPLG chips is useful for improving the reliability of radiation dosimetry in space.
NASA分類Aerospace Medicine
権利Copyright
URIhttps://repository.exst.jaxa.jp/dspace/handle/a-is/302250