タイトル | Postlaunch calibration of spacecraft attitude instruments |
著者(英) | Hashmall, J.; Davis, W.; Harman, R.; Garrick, J. |
著者所属(英) | NASA Goddard Space Flight Center |
発行日 | 1993-01-01 1993 |
言語 | eng |
内容記述 | The accuracy of both onboard and ground attitude determination can be significantly enhanced by calibrating spacecraft attitude instruments (sensors) after launch. Although attitude sensors are accurately calibrated before launch, the stresses of launch and the space environment inevitably cause changes in sensor parameters. During the mission, these parameters may continue to drift requiring repeated on-orbit calibrations. The goal of attitude sensor calibration is to reduce the systematic errors in the measurement models. There are two stages at which systematic errors may enter. The first occurs in the conversion of sensor output into an observation vector in the sensor frame. The second occurs in the transformation of the vector from the sensor frame to the spacecraft attitude reference frame. This paper presents postlaunch alignment and transfer function calibration of the attitude sensors for the Compton Gamma Ray Observatory (GRO), the Upper Atmosphere Research Satellite (UARS), and the Extreme Ultraviolet Explorer (EUVE). |
NASA分類 | SPACECRAFT INSTRUMENTATION |
レポートNO | 95A85792 |
権利 | Copyright |
|