タイトル | Time to detection of circulating microbubbles as a risk factor for symptoms of altitude decompression sickness |
著者(英) | Gilbert, John H., III; Powell, Michael R.; Calkins, Dick S.; Waligora, James M.; Kumar, K. V. |
著者所属(英) | NASA Johnson Space Center |
発行日 | 1992-11-01 |
言語 | eng |
内容記述 | This study investigated the association between time at onset of circulating microbubbles (CMB) and symptoms of altitude decompression sickness (DCS), using Cox proportional hazard regression models. The study population consisted of 125 individuals who participated in direct ascent, simulated extravehicular activities profiles. Using individual CMB status as a time-dependent variable, we found that the hazard for symptoms increased significantly (at the end of 180 min at altitude) in the presence of CMB (Hazard Ratio = 29.59; 95 percent confidence interval (95 percent CI) = 7.66-114.27), compared to no CMB. Further examination was conducted on the subgroup of individuals who developed microbubbles during the test (n = 49), by using Cox regression. Individuals with late onset of CMB (greater than 60 min at altitude) showed a significantly reduced risk of symptoms (hazard ratio = 0.92; 95 percent CI = 0.89-0.95), compared to those with early onset (equal to or less than 60 min), while controlling for other risk factors. We conclude that time to detection of circulating microbubbles is an independent determinant of symptoms of DCS. |
NASA分類 | AEROSPACE MEDICINE |
レポートNO | 93A16153 |
権利 | Copyright |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/322016 |
|