タイトル | Design and performance analysis of the CLAES Ne/CO2 cryostat |
著者(英) | Ngai, C. S.; Read, D. C.; Nast, T. C.; Naes, L. G.; Horsley, W. J. |
発行日 | 1989-01-01 |
言語 | eng |
内容記述 | The design of the dual-stage Ne/CO2 cryostat, constructed for the Cryogenic Limb Array Etalon Spectrometer (CLAES) for the cooling, to their respective required operation temperatures, of the focal plane (to less than 15 K), spectrometer (to less than 30 K), telescope (to less than 150 K), and baffles (to less than 180 K) is described, and the cryostat's performance is analyzed. The results of this study show that the current cryostat will meet all sensor cooling requirements. The cryostat weighs 2276 lbs, of which 988 lbs are charged to the neon and 484 lbs are charged to the CO2. Schematic diagrams of the CLAES cooler/sensor and of the external plumbing are presented together with the test data. |
NASA分類 | ENGINEERING (GENERAL) |
レポートNO | 90A11289 |
権利 | Copyright |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/360221 |
|