JAXA Repository / AIREX 未来へ続く、宙(そら)への英知

このアイテムに関連するファイルはありません。

タイトルDesign and calculated performance and cost of the ECAS Phase II open cycle MHD power generation system
著者(英)Harris, L. P.
著者所属(英)General Electric Co.
発行日1977-11-01
言語eng
内容記述A 2000 MWe MHD/steam plant for central station applications has been designed and costed as part of the Energy Conversion Alternatives Study (ECAS). This plant is fueled by Illinois No. 6 coal, rejects heat through mechanical draft wet cooling towers, and includes coal processing equipment, seed reprocessing, electrical inversion of the MHD generator output and emission controls to current EPA standards. It yields an estimated overall efficiency of 0.483 (7066 Btu/kWe-hr), a capital cost of $718 per kWe (1975 dollars), and a cost of electricity at 65% capacity factor of 32 mills per kWe-hr. If the assumed life and reliability could be achieved with these performance parameters, the MHD system should prove attractive.
NASA分類PLASMA PHYSICS
レポートNO78A33143
ASME PAPER 77-WA/ENER-5
権利Copyright
URIhttps://repository.exst.jaxa.jp/dspace/handle/a-is/433019