JAXA Repository / AIREX 未来へ続く、宙(そら)への英知

このアイテムに関連するファイルはありません。

タイトルIntravascular bubbles associated with intravenous injections and altitude
著者(英)Holden, R. D.; Olson, R. M.; Cooke, J. P.
著者所属(英)School of Aerospace Medicine
発行日1976-09-01
言語eng
内容記述Ultrasonically detected microbubbles were more abundant in the pulmonary artery of dogs intravenously injected with 10 ml of saline than in the same noninjected control during 10,000 ft (3,048 m), 20,000 ft (6,096 m), and 40,000 ft (12,121 m) exposures. Continuous intravenous (i.v.) drip infusions also introduced many small bubbles. Since they may serve as 'nuclei' for visible intravascular bubble formation, are sometimes associated with decompression sickness, and are additionally considered undesirable, it would appear prudent to minimize i.v. injections immediately before flights. However, a 10-min delay before ascent wil reduce their number and a 60-min delay will insure their almost complete absence. Also, slow ascent, a 1-h denitrogenation time, or use of a degassed solution will help reduce their total number.
NASA分類LIFE SCIENCES (GENERAL)
レポートNO76A46311
権利Copyright
URIhttps://repository.exst.jaxa.jp/dspace/handle/a-is/441657


このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。