タイトル | Examination of the X-ray piping diagnostic system using EGS4: Measuring the thickness of a pipe with rust when the pipe is filled with water |
その他のタイトル | EGS4を用いたX線パイプ診断システムの検証:水で満たした錆びたパイプの厚さの測定 |
著者(日) | 梶原 曉 |
著者(英) | Kajiwara, Gyo |
著者所属(日) | 清水建設 技術研究所 |
著者所属(英) | Shimizu Corporation Institute of Technology |
発行日 | 2003-01 |
刊行物名 | Proceedings of the Tenth EGS4 Users' Meeting in Japan Proceedings of the Tenth EGS4 Users' Meeting in Japan |
開始ページ | 15 |
終了ページ | 18 |
刊行年月日 | 2003-01 |
言語 | eng |
抄録 | In a series of papers entitled 'Examination of the X-ray piping diagnostic system using EGS4' presented at the proceedings of the EGS4 users' meetings, the possibility of measuring the thickness of piping walls with rust was discussed. Last year, it was described, based on the earlier results, how the thickness of steel pipes with rust can be measured in an empty pipe. The thickness of the steel determined by using the diagram made by using EGS4 simulation, agreed well with the actual steel thickness obtained by the experiments. In this paper, it is described how to use the same procedure to measure the thickness of pipes filled with water and the result obtained is described. |
キーワード | EGS4; Monte Carlo simulation; X-ray; rusted steel pipe; thickness; diagnosis; research and development; EGS4; モンテカルロシミュレーション; X線; 錆びた鉄パイプ; 厚さ; 診断; 研究開発 |
資料種別 | Conference Paper |
SHI-NO | AA0045018003 |
レポートNO | KEK-Proceedings-2002-18 |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/46653 |