| タイトル | Non-inertial calibration of vibratory gyroscopes |
| 本文(外部サイト) | http://hdl.handle.net/2060/20080007072 |
| 著者(英) | Tang, Tony K.; Gutierrez, Roman C. |
| 著者所属(英) | California Inst. of Tech. |
| 発行日 | 2003-07-29 |
| 言語 | eng |
| 内容記述 | The electrostatic elements already present in a vibratory gyroscope are used to simulate the Coriolis forces. An artificial electrostatic rotation signal is added to the closed-loop force rebalance system. Because the Coriolis force is at the same frequency as the artificial electrostatic force, the simulated force may be introduced into the system to perform an inertial test on MEMS vibratory gyroscopes without the use of a rotation table. |
| NASA分類 | Instrumentation and Photography |
| 権利 | No Copyright |