JAXA Repository / AIREX 未来へ続く、宙(そら)への英知

このアイテムに関連するファイルはありません。

タイトルUncertainty in Calibration, Detection and Estimation of Metal Concentrations in Engine Plumes Using OPAD
本文(外部サイト)http://hdl.handle.net/2060/19990010019
著者(英)Benzing, Daniel A.; Hopkins, Randall C.
著者所属(英)Alabama Univ.
発行日1998-09-01
言語eng
内容記述Improvements in uncertainties in the values of radiant intensity (I) can be accomplished mainly by improvements in the calibration process and in minimizing the difference between the background and engine plume radiance. For engine tests in which the plume is extremely bright, the difference in luminance between the calibration lamp and the engine plume radiance can be so large as to cause relatively large uncertainties in the values of R. This is due to the small aperture necessary on the receiving optics to avoid saturating the instrument. However, this is not a problem with the SSME engine since the liquid oxygen/hydrogen combustion is not as bright as some other fuels. Applying the instrumentation to other type engine tests may require a much brighter calibration lamp.
NASA分類Spacecraft Propulsion and Power
権利No Copyright


このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。