JAXA Repository / AIREX 未来へ続く、宙(そら)への英知

このアイテムに関連するファイルはありません。

タイトルThe calculation of 3D saptial dose distribution around a shielded vaginal cylinder with iridium-192 source calculated by using Monte Carlo code EGS4
その他のタイトルモンテカルロ・コードEGS4を用いて計算したIridium-192線源による遮蔽した鞘状円筒周囲の3次元線量位置分布の計算
著者(日)Chen, I. J.; Sheu, R. D.; Chang, B. J.; Liu, Y. M.; Chao, L. S.; Yen, S. H.
著者(英)Chen, I. J.; Sheu, R. D.; Chang, B. J.; Liu, Y. M.; Chao, L. S.; Yen, S. H.
著者所属(日)Institute of Nuclear Energy Research; National Tsing Hua University; Institute of Nuclear Energy Research; Taipei Veterans General Hospital Cancer Therapy Center; Taipei Veterans General Hospital Cancer Therapy Center; Taipei Veterans General Hospital Cancer Therapy Center
著者所属(英)Institute of Nuclear Energy Research; National Tsing Hua University; Institute of Nuclear Energy Research; Taipei Veterans General Hospital Cancer Therapy Center; Taipei Veterans General Hospital Cancer Therapy Center; Taipei Veterans General Hospital Cancer Therapy Center
発行日2000-08-08
刊行物名Proceedings of the Second International Workshop on EGS
Proceedings of the Second International Workshop on EGS
開始ページ107
終了ページ114
刊行年月日2000-08-08
言語eng
抄録According to the previous study on the dose distribution around a shielded vaginal cylinder with a high-intensity Ir-192 source by using EGS4 code, the more detailed 3D-simulation model was established in this work. The results obtained by the 3D-simulation model were compared with those measured by ion chamber in previous work and evaluated by the existing treatment planning system. These results show good agreement. Furthermore, the 3D spatial dose distribution around a unit intensity Ir-192 source was calculated at each probable position in the vaginal cylinder with 90, 180, 270 deg tungsten shield and no shield cases. Those results save as a database which could be accessed through the graphical user interface developed by IDL(sup TM) to display dose distributions in 1D, 2D, and 3D plot under any combination of source intensity at each position, and shielding situation. It demonstrates a prototype of the brachytherapy treatment planning system based on the Monte Carlo EGS4 code.
キーワードthree dimensional dose distribution; shielded vaginal cylinder; Ir-192 source; radiation therapy; Monte Carlo simulation; electron photon cascade; graphical user interface; research and development; EGS4; 3次元線量分布; 遮蔽した鞘状円筒; Ir-192線源; 放射線治療; モンテカルロシミュレーション; 電子・光子カスケード; グラフィック・ユーザー・インタフェース; 研究開発; EGS4
資料種別Conference Paper
SHI-NOAA0029759012
レポートNOKEK-Proceedings-2000-20
URIhttps://repository.exst.jaxa.jp/dspace/handle/a-is/55651


このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。