タイトル | Fire testing in the Boeing 707 cabin section |
本文(外部サイト) | http://hdl.handle.net/2060/19790003861 |
著者(英) | Tustin, E. A. |
著者所属(英) | Boeing Commercial Airplane Co. |
発行日 | 1978-10-01 |
言語 | eng |
内容記述 | The goal of a FIREMEN funded contract is the definition of a laboratory test method ranking airplane interior materials by probable performance in post-crash and in-flight fires. A major task is the relation of laboratory results to full scale data. A large test facility for testing materials to the thermal threat of fuel fed and interior fires was developed with quartz lamps and a propane burner in a twenty foot fuselage section. A method was developed to analyze full scale data for the apparent heat, smoke and toxicant release rates of the material tested. |
NASA分類 | AIR TRANSPORTATION AND SAFETY |
レポートNO | 79N12032 |
権利 | No Copyright |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/569286 |