| タイトル | The Evaluation and Improvement of Microbial Analysis Methods and Techniques in the Johnson Space Center Microbiology Laboratory |
| 本文(外部サイト) | http://hdl.handle.net/2060/20160011281 |
| 著者(英) | St. Pierre, Ashley L.; Ott, C. Mark; Smith, Melanie J.; Dunbar, Brandon J. |
| 著者所属(英) | NASA Johnson Space Center |
| 発行日 | 2016-08-11 |
| 言語 | eng |
| 内容記述 | Microbial contamination is a risk to crew health both on the ground and on the International Space Station. The methods and techniques of microbial analysis for surfaces and items on board a spacecraft are an important aspect of ensuring that crew health is not at unnecessary risk. This series of projects seeks to improve and optimize microbial analysis methods, such as the recovery of bacteria from difficult surfaces, and the analysis of long-term bacterial isolate storage techniques. These projects will help the Johnson Space Center Microbiology laboratory be more efficient at identifying and addressing microbial concerns related to spaceflight and on the ground. Fabrics are substantially more problematic for microbial monitoring than steel or glass surfaces, as bacteria tend to get trapped in the fibers. To better understand which microbial sampling method is most efficient, various methods of recovery were attempted, and the processes were revised based on the results. The final phase of testing applied the knowledge gained from the resulting methods to an acoustic blanket that is currently being used on the International Space Station, with future use slated for the Orion spacecraft. In this phase, the sample materials were inoculated with bacterial suspensions, vortexed with phosphate-saline buffer, and the liquid was plated on tryptic soy agar. The results from the test of the acoustic blanket indicate that not only is microbial growth possible on fabric that is treated for moisture-resistance, but also that contamination can occur if aseptic handling procedures are not followed. Interestingly, out of three hundred and ninety (390) plates, only seventeen (17) showed growth (4.36%), and recovery of the Staphylococcus epidermidis used to inoculate the samples only occurred on four (4) of the plates. The growth on the remaining plates was contamination by various microbes, including those commonly found on the skin and in soil. This shows that 2 while bacterial recovery is possible from fabric, it remains a problematic material, and additional tests may be needed to improve efficiency further. Microbial isolates from surface sampling are archived in -80degC freezers for future study. On multiple occasions, it was discovered that certain isolates in the Johnson Space Center Microbiology laboratory were not able to be recovered after being cultured from freezer storage. To determine if the current method of preparing bacterial isolates for long-term storage remained an effective method, a test was performed that compared the current standard with a new standard based on the manufacturer's instructions. The current method of freezer storage involves transferring a fresh culture of an organism into a freezer vial, shaking it, and putting the vial directly into the freezer. The manufacturer's instruction method is similar, but instead requires that vial is inverted only, and the majority of the cryo-liquid be removed from the vial and plated to ensure viability. After 7 days, the isolates were removed from the freezer and cultured. After 24 hours, growth was checked and recorded as presence or absence. With the exception of the Ralstonia pickettii isolate, all cultures showed normal growth. An additional test was performed exploring the viability of isolates stored earlier in the year. Five R. pickettii and five Staphylococcus epidermidis isolates were removed from the freezer and cultured. The growth from this test showed that all of the organisms were viable, with the exception of one R. pickettii isolate. These results indicate that the current method of preparing bacterial isolates for long-term storage is effective, and perhaps it would not be efficient to make any changes to the process. It is possible that the original R. pickettii samples were processed incorrectly and thus were not viable when put into storage. In the course of these projects, test protocols were developed and improved. The Johnson Space Center Microbiology laboratory will be able to use these protocols in the future to further improve and optimize microbial monitoring of spacecraft surfaces. |
| NASA分類 | Exobiology; Aerospace Medicine |
| レポートNO | JSC-CN-37236 |
| 権利 | Copyright, Distribution as joint owner in the copyright |
| URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/574443 |
|