タイトル | Radiometric Calibration and Stability of the Landsat-8 Operational Land Imager (OLI) |
本文(外部サイト) | http://hdl.handle.net/2060/20160013713 |
著者(英) | Markham, Brian L.; Kaita, Edward; Haque, Md Obaidul; Morfitt, Ron; Barsi, Julia A.; Ong, Lawrence |
著者所属(英) | NASA Goddard Space Flight Center |
発行日 | 2015-08-09 |
言語 | eng |
内容記述 | Landsat-8 and its two Earth imaging sensors, the Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) have been operating on-orbit for 2 1/2 years. The OLI radiometric calibration, which is monitored using on-board lamps, on-board solar diffusers, the moon and vicarious calibration techniques has been stable to within 1% over this period of time. The Coastal Aerosol band, band 1, shows the largest change at about 1% over the period; all other bands have shown no significant trend. OLI bands 1- 4 show small discontinuities in response (+0.1% to 0.2%) beginning about 7 months after launch and continuing for about 1 month associated with a power cycling of the instrument, though the origin of the recovery is unclear. To date these small changes have not been compensated for, but this will change with a reprocessing campaign that is currently scheduled for Fall 2015. The calibration parameter files (each typically covering a 3 month period) will be updated for these observed gain changes. A fitted response to an adjusted average of the lamps, solar and lunar results will represent the trend, sampled at the rate of one value per CPF. |
NASA分類 | Earth Resources and Remote Sensing |
レポートNO | GSFC-E-DAA-TN25560 |
権利 | Copyright, Distribution as joint owner in the copyright |
|