JAXA Repository / AIREX 未来へ続く、宙(そら)への英知

このアイテムに関連するファイルはありません。

タイトルUpdates of the KArLE Experiment: New Libs Calibration Under High Vacuum for the Quantification of Potassium in Basalt for In Situ Geochronology
本文(外部サイト)http://hdl.handle.net/2060/20140012502
著者(英)Li, Z.-H.; Miller, J. S.; Devismes, D.; Cohen, B. A.
発行日2014-07-14
言語eng
内容記述In planetary exploration, in situ absolute geochronology is one of the main important measurements that needs to be accomplished. Until now, on Mars, the age of the surface is only determined by crater density counting, which gives relative ages. These ages can have a lot of uncertainty as they depend on many parameters. More than that, the curves must be ties to absolute ages. Thus far, only the lost lander Beagle 2 was designed to conduct absolute geochronology measurements, though some recent attempts using MSL Curiosity show that this investigation is feasible and should be strongly encouraged for future flight. Experimental: The Potassium (K)-Argon Laser Experiment (KArLE) is being developed at MSFC through the NASA Planetary Instrument Definition and Development Program (PIDDP). The goal of this experiment is to provide in situ geochronology based on the K-Ar method. A laser ablates a rock under high vacuum, creating a plasma which is sensed by an optical spectrometer to do Laser Induced Breakdown Spectroscopy (LIBS). The ablated material frees gases, including radiogenic 40Ar,which is measured by a mass spectrometer (MS). As the potassium is a content and the 40Ar is a quantity, the ablated mass needed in order to relate them. The mass is given by the product of the ablated volume by the density of this material. So we determine the mineralogy of the ablated material with the LIBS spectra and images and calculate its density. The volume of the pit is measured by using microscopy. LIBS measurement of K under high vacuum: Three independant projects [1, 2, 3] including KArLE, are developing geochronological instruments based on this LA-LIBS-MS method. Despite several differences in their setup, all of them have validated the methods with analyses and ages. However, they all described difficulties with the LIBS measurements of K [3,4]. At ambient pressure, the quantification of K by LIBS on geological materials can be accurate [5]. However the protocol of the LA-LIBS-MS experiment required hundreds of shots under high vacuum in order to free enough 40Ar* to be measured by the QMS. This long duration of ablation may induces significant changes in the LIBS spectra. The pressure may increases by orders of magnitudewithin the chamber and the laser pit geometry can change the effectiveness of ablation and intensity of plasma light received. These effects introduce variation between the first and last spectra and so the quantification of K is more complex. The ablation of one crater can give, depending on the protocol of acquisition, from tens to hundreds of spectra. Protocol and results: We are in the process of further characterizing the variation introduced into LIBS spectra by the use of hundreds of laser shots, and definining a protocol that can be used to ensure accuracy and reporoducibility in the results.We are using natural rock powder standards fused in a furnace, as well as mars analog samples with known K content. We will show the result of the calibration and some new statistical approaches in order to apprehend the effects of the long time ablation on rocks under high vacuum.
NASA分類Geosciences (General); Lunar and Planetary Science and Exploration
レポートNOM14-3632
権利Copyright, Distribution as joint owner in the copyright


このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。