タイトル | Circular Scan Streak Tube Development |
本文(外部サイト) | http://hdl.handle.net/2060/19800024703 |
著者(英) | Nevin, S. |
著者所属(英) | ITT Electro-Optical Products Div. |
発行日 | 1980-07-01 |
言語 | eng |
内容記述 | A streak tube having circular scan was designed, built and tested. Continuous circular scan, easily derived from out of phase sine waves applied to the conventional deflection plates, permits the timing of pulses traveling long baselines. At the tube's output a circular array of 720 elements is scanned to provide 30 to 40 picosecond resolution. Initial difficulties with electron bombarded silicon arrays were circumvented by using microchannel plates within the streak tube to provide the needed electronic amplification and digital sensitivity and coupling the 720 element arrays to the electron beam by means of a phosphor on a fiber optics. Two ceramic body tubes with S-20 photocathodes were tested and delivered. |
NASA分類 | OPTICS |
レポートNO | 80N33211 NASA-CR-160029 |
権利 | No Copyright |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/70060 |
|