タイトル | Power Coupling Alternatives for the NEP Thermionic Power System |
本文(外部サイト) | http://hdl.handle.net/2060/19790013376 |
著者(英) | Manda, M. L.; Fitzpatrick, G. O.; Britt, E. J. |
著者所属(英) | Rasor Associates, Inc.|Jet Propulsion Lab., California Inst. of Tech. |
発行日 | 1978-12-01 |
言語 | eng |
内容記述 | Three output power coupling methods which can eliminate the high temperature insulator from the Nuclear Electric Propulsion (NEP) power system are described and estimates of their effects on the NEP system masses and cooling requirements are presented. Nominal 400 kWe power systems using push-pull and flux reset inductive output coupling are shown to have specific masses of 22.2 kg/kWe and 18.8 kg/kWe, respectively. Series connected heat pipe systems, which use the heat pipe-to-heat pipe resistance to isolate converters on adjacent heat pipes, are shown to have specific masses 0.5 to 1.4 kg/kWe lower than the NEP baseline system. Increasing the number and temperature of the heat pipes in the system without changing the electric output reduces the calculated system specific mass only slightly, whereas increasing the output power significantly reduces the specific mass. Estimates of cooling requirements indicate that 11-45 sq m of power conditioning radiator are needed. A possible location for the power conditioning radiator may be in the present location of the kapton sputter shield. |
NASA分類 | ENERGY PRODUCTION AND CONVERSION |
レポートNO | 79N21547 NASA-CR-158372 NSR-7-1 |
権利 | No Copyright |
URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/71898 |