タイトル | Magnet Architectures and Active Radiation Shielding Study - SR2S Workshop |
本文(外部サイト) | http://hdl.handle.net/2060/20140003415 |
著者(英) | Washburn, Scott; Nerolich, Shaun; Meinke, Rainer; Burger, William; Ilin, Andrew; Westover, Shane |
発行日 | 2014-04-09 |
言語 | eng |
内容記述 | Analyze new coil configurations with maturing superconductor technology -Develop vehicle-level concept solutions and identify engineering challenges and risks -Shielding performance analysis Recent advances in superconducting magnet technology and manufacturing have opened the door for re-evaluating active shielding solutions as an alternative to mass prohibitive passive shielding.Publications on static magnetic field environments and its bio-effects were reviewed. Short-term exposure information is available suggesting long term exposure may be okay. Further research likely needed. center dotMagnetic field safety requirements exist for controlled work environments. The following effects have been noted with little noted adverse effects -Magnetohydrodynamic (MHD) effects on ionized fluids (e.g. blood) creating an aortic voltage change -MHD interaction elevates blood pressure (BP) center dot5 Tesla equates to 5% BP elevation -Prosthetic devises and pacemakers are an issue (access limit of 5 gauss). |
NASA分類 | Space Radiation; Spacecraft Design, Testing and Performance |
レポートNO | JSC-CN-30881 |
権利 | Copyright, Distribution as joint owner in the copyright |