タイトル | Description of 103 Cases of Hypobaric Sickness from NASA-sponsored Research |
本文(外部サイト) | http://hdl.handle.net/2060/20030063917 |
著者(英) | Acock, Keena E.; Klein, Jill S.; Conkin, Johnny |
著者所属(英) | NASA Johnson Space Center |
発行日 | 2003-07-01 |
言語 | eng |
内容記述 | One hundred and three cases of hypobaric decompression sickness (DCS) are documented, with 6 classified as Type II DCS. The presence and grade of venous gas emboli (VGE) are part of the case descriptions. Cases were diagnosed from 731 exposures in 5 different altitude chambers from 4 different laboratories between the years 1982 and 1999. Research was funded by NASA to develop operational prebreathe (PB) procedures that would permit safe extravehicular activity from the Space Shuttle and International Space Station using an extravehicular mobility unit (spacesuit) operated at 4.3 psia. Both vehicles operate at 14.7 psia with an "air" atmosphere, so a PB procedure is required to reduce nitrogen partial pressure in the tissues to an acceptable level prior to depressurization to 4.3 psia. Thirty-two additional descriptions of symptoms that were not diagnosed as DCS together with VGE information are also included. The information for each case resides in logbooks from 32 different tests. Additional information is stored in the NASA Decompression Sickness Database and the Prebreathe Reduction Protocol Database, both maintained by the Environmental Physiology Laboratory at the Johnson Space Center. Both sources were reviewed to provide the narratives that follow. |
NASA分類 | Aerospace Medicine |
レポートNO | NASA/TM-2003-212052 NAS 1.15:212052 |
権利 | No Copyright |