| タイトル | Skin Temperatures During Unaided Egress: Unsuited and While Wearing the NASA Launch and Entry or Advanced Crew Escape Suits |
| 本文(外部サイト) | http://hdl.handle.net/2060/20000048257 |
| 著者(英) | Schneider, Suzanne M.; Greenisen, Michael C.; Woodruff, Kristin K.; Lee, Stuart M. C. |
| 著者所属(英) | NASA Johnson Space Center |
| 発行日 | 2000-03-01 |
| 言語 | eng |
| 内容記述 | The two flight suits currently worn by crew members during Shuttle launch and landing, the Launch and Entry Suit (LES) and the Advanced Crew Escape Suit (ACES), are designed to protect crew members in the case of emergency. Although the Liquid Cooling Garment (LCG) worn under the flight suits was designed to counteract the heat storage of the suits, the suits may increase thermal stress and limit the astronaut's egress capabilities. The purpose of this study was to assess the thermal loads experienced by crew members during a simulated emergency egress before and after spaceflight. Comparisons of skin temperatures were made between the preflight unsuited and suited conditions. between the pre- and postflight suited conditions, and between the two flight suits. |
| NASA分類 | Man/System Technology and Life Support |
| レポートNO | S-853 NASA/TM-2000-209761 NAS 1.15:209761 |
| 権利 | No Copyright |
| URI | https://repository.exst.jaxa.jp/dspace/handle/a-is/94810 |